首页> 外文期刊>Concrete >Cracks lead to corrosion
【24h】

Cracks lead to corrosion

机译:裂纹导致腐蚀

获取原文
获取原文并翻译 | 示例
           

摘要

Acommon myth is that cracks in concrete lead to the corrosion of the underlying reinforcement. A casual inspection of concrete with corroding reinforcement, such as that in Figure 1, supports this mistaken view as there is often a crack associated with the rusting reinforcement. The actual mechanism for the majority of cases where corrosion of reinforcement occurs is the permeation of chlorides or carbon dioxide through the cover concrete, which combined with moisture and oxygen leads to corrosion of the reinforcement. The expansive nature of the corrosion reaction pushes the concrete off the reinforcement, causing cracking, through which the visible corrosion products leak, as shown in Figure 1.
机译:普遍的神话是混凝土中的裂缝会导致底层钢筋的腐蚀。随便检查带有腐蚀钢筋的混凝土,如图1所示,这支持了这种错误的看法,因为生锈的钢筋经常会出现裂缝。在大多数情况下,发生钢筋腐蚀的实际机理是氯化物或二氧化碳渗透到覆盖混凝土中,再加上水分和氧气会导致钢筋腐蚀。腐蚀反应的膨胀性质将混凝土推离钢筋,导致开裂,可见的腐蚀产物通过开裂泄漏,如图1所示。