Amelioration de l'essai d'ecoulement des sables

机译:砂流测试的改进

获取原文
获取原文并翻译 | 示例
           

摘要

This study's objective is twofold: to gain an understanding of the causes of poor reliability in the sand flow test with a 0.08/2-mm particle size fraction, as set forth in French standards NF P 18-564 and European standards NF EN 933-6; and to propose an economical and efficient solution for improving this reliability. The study indicates that 90% of inter-laboratory variance, which is responsible for poor testing reliability, can be explained by uncertainty as the operator introduces a sand sample into the flow unit. In seeking to reduce this level of uncertainty, a prototype feeder was designed and then evaluated. Test results showed that the presence of a feeder served to decrease this uncertainty to a negligible amount. By using the prototype feeder developed at the CECP prototype center in Rouen (Normandy), it would seem that reproducibility of the sand flow test may be divided by a factor of three. This finding, which solidly meets category requirements stipulated in both French and European product standards (XP P 18-540 and NF EN 13043, respectively), will be the focus of an upcoming validation effort within the scope of a cross-testing experiments.
机译:这项研究的目的是双重的:按照法国标准NF P 18-564和欧洲标准NF EN 933-的规定,了解粒径为0.08 / 2mm的沙流测试中可靠性不佳的原因。 6;并提出一种经济有效的解决方案来提高这种可靠性。研究表明,由于操作员将砂样引入流动单元,不确定性可以解释实验室间差异的90%,这是导致测试可靠性差的原因。为了减少这种不确定性,设计了原型进料器,然后进行了评估。测试结果表明,进料器的存在可将这种不确定性降低到可以忽略的程度。通过使用在鲁昂(诺曼底)CECP原型中心开发的原型进料器,砂流测试的可重复性似乎可以除以三。这一发现完全符合法国和欧洲产品标准(分别为XP P 18-540和NF EN 13043)中规定的类别要求,将成为交叉测试实验范围内即将进行的验证工作的重点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号