首页> 外文期刊>Architectural science review >The influence of roof reflectivity on adjacent air and surface temperatures
【24h】

The influence of roof reflectivity on adjacent air and surface temperatures

机译:屋顶反射率对邻近空气和地面温度的影响

获取原文
获取原文并翻译 | 示例
           

摘要

An experimental study was conducted to answer questions about the thermal effects of roof reflectivity on the neighbouring built environment. Temperatures were recorded at the surface of black ethylene propylene diene monomer (EPDM) and white thermoplastic polyolefin (TPO) membrane overlay areas; in the air and at electrical metallic tubing (EMT) above them; and at opaque and glazed wall surfaces adjacent to them. The surface of the EPDM roof was significantly hotter than the TPO roof by 36℃ and 26℃ on two test dates. Air temperatures were 2°C higher above EPDM versus TPO up to 14 cm, with no significant differences above this height. Temperatures were 2°C higher at EMT above the TPO surface than above the EPDM. A precast concrete panel wall was 3-5°C warmer adjacent to TPO versus EPDM. Exterior glazing surface temperatures were 2℃ warmer adjacent to TPO versus EPDM.
机译:进行了一项实验研究,以回答有关屋顶反射率对邻近建筑环境的热效应的问题。记录了黑色乙烯丙烯二烯单体(EPDM)和白色热塑性聚烯烃(TPO)膜覆盖区域表面的温度;在空气中以及上方的金属电管(EMT)中;以及与它们相邻的不透明玻璃表面。在两个测试日期,EPDM屋顶的表面温度分别比TPO屋顶高36℃和26℃。空气温度比EPDM高出14°C,而EPDM则高出2°C,在此高度以上没有明显差异。在TPO表面上方的EMT处的温度比在EPDM上方的温度高2°C。 TPO与EPDM相邻的预制混凝土面板墙温度高3-5°C。 TPO与EPDM相比,外部玻璃表面温度高2℃。